oil level RENAULT TWINGO 2009 2.G Sequential Transmission Workshop Manual

Page 44 of 138

21B-44
MR-413-X44-21B000$413.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No.: 04
21B
DF078
PRESENT
OR
STOREDHYDRAULIC CONTROL
1.DEF: Signal outside lower limit
NOTESPriorities when dealing with a number of faults:
Apply the interpretation of other faults first.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present during a road test.
Special note:
Improper use of the gear lever when stationary may lead to this fault.
Using the diagnostic tool, via parameter PR018 Hydraulic pressure, check that the pump is activated at 40 bar
and stops at 50 bar.
Pressure level below a pressure threshold.
Fault linked to a lack of oil (internal or external leak) or to a pump failure.
Repair or replace if necessary (see MR 411 Mechanical, 21B, Sequential gearbox, Electric pump assembly
oil: Specifications).
Case of excessive pump operation:
–Internal or external leak in the circuit. For an external leak, locate the leak and repair if necessary. If there is an
internal leak, replace the hydraulic unit (see MR 411 Mechanical, 21B, Sequential gearbox,
Electrohydraulic unit: Removal - Refitting).
If the fault is still present, replace the accumulator (see MR 411 Mechanical, 21B, Sequential gearbox,
Pressure accumulator: Removal - Refitting).
AFTER REPAIRDeal with any faults displayed by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_DF078

Page 60 of 138

21B-60
MR-413-X44-21B000$472.mif
V2
SEQUENTIAL GEARBOX
Fault finding - Interpretation of faults
Vdiag No: 04
21B
DF166
CONTINUED
1.DEF
NOTESNone
Check the level of oil in the discharged accumulator, refer to the interpretation of command AC081 Discharge
pressure accumulator.
Check the condition and position of the 30 A fuse for the pump in the engine compartment.
Use command AC012 “Hydraulic pump relay” with the diagnostic tool and check that the pump assembly is
working. If the pump is not working, perform the necessary repairs.
If the fault is still present, replace the oil pressure sensor (see MR 411, Sequential gearbox, solenoid valve unit
pressure sensor, Removal refitting).
Switch off the ignition.
Switch on the ignition again and carry out a new check using the diagnostic tool.
Replace the pump assembly if the fault reappears (see MR 411, Sequential gearbox, pump assembly,
Removal refitting).
AFTER REPAIRDeal with any faults detected by the diagnostic tool.
Clear the computer memory.
Carry out a road test followed by another check with the diagnostic tool.

Page 138 of 138

21B -138
MR-413-X44-21B000$944.mif
V2
SEQUENTIAL GEARBOX
Diagnostic - Fault finding chart
Vdiag No: 04
21B
ALP 12 Vehicle jumps when engine is started
NOTESSpecial notes:
Only consult this customer complaint after a complete check with the diagnostic tool.
If a gear was engaged when there is a request to start the engine check the oil level in the sequential gearbox
circuit.
Check the operation of the brake pedal switch as well as the condition of the gear lever switches (consult the
interpretation of statuses: ET043 “Lever switch no. 0”, ET044 “Lever switch no. 1”, ET045 “Lever switch
no. 2” and ET046 “Lever switch no. 3”).
Ensure that the cylinder and the clutch fork are operating correctly (damage, seizing, part breakage, etc.).
AFTER REPAIRClear the computer fault memory. Switch off the ignition and wait 20 seconds.
Carry out a road test followed by another check with the diagnostic tool.
BVRJH1_V04_ALP12